3 physical block transmitter – INOR PROFIPAQ-L User Manual
Page 33

33
0
86
25
INPUT_FAULT_1
SIMPLE
U8
STORE_D 1
READ
0
87
26
INPUT_FAULT_2
SIMPLE
U8
STORE_D 1
READ
0
88
27
SENSOR_WIRE_CHECK_1
SIMPLE
U8
STORE_S 1
RW
0
89
28
SENSOR_WIRE_CHECK_2
SIMPLE
U8
STORE_S 1
RW
0
90
29
MAX_SENSOR_VALUE_1
SIMPLE
FLOAT
STORE_N 4
RW
0
91
30
MIN_SENSOR_VALUE_1
SIMPLE
FLOAT
STORE_N 4
RW
0
92
31
MAX_SENSOR_VALUE_2
SIMPLE
FLOAT
STORE_N 4
RW
0
93
32
MIN_SENSOR_VALUE_2
SIMPLE
FLOAT
STORE_N 4
RW
0
94
33
RJ_TEMP
SIMPLE
FLOAT
STORE_D 4
READ
0
95
34
RJ_TYPE
SIMPLE
U8
STORE_S 1
RW
0
96
35
EXTERNAL_RJ_VALUE
SIMPLE
FLOAT
STORE_S 4
RW
0
97
36
SENSOR_CONNECTION
SIMPLE
U8
STORE_S 1
RW
0
98
37
COMP_WIRE1
SIMPLE
FLOAT
STORE_S 4
RW
0
99
38
COMP_WIRE2
SIMPLE
FLOAT
STORE_S 4
RW
0
100
39
EMISSIVITY
SIMPLE
FLOAT
STORE_S 4
RW
0
101
40
PEAK_TRACK
SIMPLE
U8
STORE_S 1
RW
0
102
41
DECAY_RATE
SIMPLE
FLOAT
STORE_S 4
RW
0
103
42
PEAK_TIME
SIMPLE
FLOAT
STORE_S 4
RW
0
104
43
TRACK_HOLD
SIMPLE
U8
STORE_S 1
RW
0
105
44
SPECT_FLT_SET
SIMPLE
U8
STORE_S 1
RW
0
106
45
TAB_ENTRY
SIMPLE
U8
STORE_D 1
RW
0
107
46
TAB_X_Y_VALUE
ARRAY
FLOAT
STORE_D 8
RW
0
108
47
TAB_MIN_NUMBER
SIMPLE
U8
STORE_N 1
READ
0
109
48
TAB_MAX_NUMBER
SIMPLE
U8
STORE_N 1
READ
0
110
49
TAB_OP_CODE
SIMPLE
U8
STORE_D 1
RW
0
111
50
TAB_STATUS
SIMPLE
U8
STORE_S 1
READ
0
112
51
TAB_ACTUAL_NUMBER
SIMPLE
U8
STORE_N 1
READ
6.3 Physical Block Transmitter
0
126
0
BLOCK_OBJECT
RECORD DS_32
STORE_C 20
READ
0
127
1
ST_REV
SIMPLE
U16
STORE_N 2
READ
0
128
2
TAG_DESCR
SIMPLE
OCSTR
STORE_S 32
RW
0
129
3
STRATEGY
SIMPLE
U16
STORE_S 2
RW
0
130
4
ALERT_KEY
SIMPLE
U8
STORE_S 1
RW
0
131
5
TARGET_MODE
SIMPLE
U8
STORE_S 1
RW
0
132
6
MODE_BLK
RECORD DS_37
STORE_D 3
READ
0
133
7
ALARM_SUM
RECORD DS_42
STORE_D 8
READ
0
134
8
SW_REVISION
SIMPLE
VISTR
STORE_C 16
READ
0
135
9
HW_REVISION
SIMPLE
VISTR
STORE_C 16
READ
0
136
10
DEVICE_MAN_ID
SIMPLE
U16
STORE_C 2
READ
0
137
11
DEVICE_ID
SIMPLE
VISTR
STORE_C 16
READ
0
138
12
DEVICE_SER_NUM
SIMPLE
VISTR
STORE_C 16
READ
0
139
13
DIAGNOSIS
SIMPLE
OCSTR
STORE_D 4
READ
0
140
14
DIGNOSIS_EXTENSION
SIMPLE
OCSTR
STORE_D 6
READ
0
141
15
DIAGNOSIS_MASK
SIMPLE
OCSTR
STORE_C 4
READ
0
142
16
DIAGNOSIS_MASK_EXT
SIMPLE
OCSTR
STORE_C 6
READ
0
143
17
DEVICE_CERTIFICATION
SIMPLE
VISTR
STORE_C 32
READ
0
144
18
WRITE_LOCKING
SIMPLE
U16
STORE_N 2
RW
0
145
19
FACTORY_RESET
SIMPLE
U16
STORE_S 2
RW
0
146
20
DESCRIPTOR
SIMPLE
OCSTR
STORE_S 32
RW
0
147
21
DEVICE_MESSAGE
SIMPLE
OCSTR
STORE_S 32
RW
0
148
22
DEVICE_INSTALL_DATE
SIMPLE
OCSTR
STORE_S 16
RW
0
149
23
LOCAL_OP_ENA
SIMPLE
U8
STORE_N 1
RW
0
150
24
IDENT_NUMBER
SIMPLE
U8
STORE_S 1
RW
0
151
25
HW_WRITE_PROTECTION SIMPLE
U8
STORE_D 1
READ