IDEC DATAVS2 Series User Manual
Page 44
SVS2
Series
Instruction
Manual
39
It is possible to set more complex inspection processes, with acquired images processed in parallel
undergoing simple or complex measurements/controls at the same time, with the results connected to
different outputs:
Or the output may be dependant on the result of all controls/measurements: if so, the inspection will
only give a positive outcome when all controls/measurements included in it return a positive result.
The following paragraphs provide a description of each individual control with the following details:
• Description: Control operation;
• Selection: menu from which control is selected;
• Pointer shape: to facilitate positioning, each control uses a different pointer;
• Positioning: how to position and size the ROI;
• Parameters: description of configuration parameters;
• Result: description of outcome;
• Example: Explains full procedure, from selection, to setup, through to output settings.
Acquired
Image
Control /
Measurement
No. 1
Control /
Measurement
No. 2
Control /
Measurement
No. 3
Output no. 1
Pass / Fail
Output no. 2
Pass / Fail
Output no. 3
Pass / Fail
Control /
Measurement
No. 1
Control /
Measurement
No. 2
Control /
Measurement
No. 3
Acquired
Image
Output no. 1
Pass / Fail