Request sense command (03h) (continued) – Quantum 10K II User Manual
Page 253

SCSI Description
5–186
Quantum Atlas 10K II Ultra160/m SCSI Hard Disk Drives
REQUEST SENSE Command (03h) (continued)
Table 5–86 Supported Additional Sense Codes and Sense Code Qualifiers (continued)
Sense Key
Code
Qualifier
Meaning
04h HARDWARE ERROR
(continued)
40
AB
Could Not Calculate Bode Info
40
AC
Could Not Complete the Low-Level BCV
WRITE Function
40
AD
Got a Divide By Zero Error in Complex
Divide
41
00
Data Path Failure
41
86
DDMA Overrun or ACK Overrun
44
00
Logical Assertion (Firmware Consistency
Check)
44
84
Insufficient Buffer Memory for Operation
05h ILLEGAL REQUEST
1A
00
Parameter List Length Error
20
00
Invalid Command Operation Code
20
80
R4K Image Loader Bad
20
81
R4K System Micro-OCM Code Image (Not
in EEROM) Bad
20
82
R4K Diagnostic Code Image (Not in
EEROM) Bad
20
FE
ETM Cannot Run With Motor Spinning
20
FF
Selfscan Code Not Loaded or Bad
21
00
Logical Block Address Out of Range
24
00
Invalid Field in CDB
25
00
Logical Unit Not Supported
26
00
Invalid Fields in Parameters
26
02
Invalid Parameter Value
26
04
Invalid Release of Persistent Reservation
2C
00
Command Sequence Error
3D
00
Invalid Bits in IDENTIFY Message
49
00
Invalid Message Error
06h UNIT ATTENTION
0B
01
SMART Overtemperature Trip
28
00
Format Completed by Another Initiator
29
00
Power On, SCSI Bus Reset, or Bus Device
Reset Occurred
29
01
Power On Occurred
29
02
SCSI Bus Reset Occurred
(continued)