Battery

4.5.1

Operating Principles

)

Primary use/charging

The battery must be charged prior to using it for the first time because it is deliv-
ered with an energy content as low as possible.

For new batteries or batteries that have been stored for a long time (> three
months), it is effectual to make only one charge/discharge cycle.

For Li-Ion batteries, a single discharging and charging cycle is sufficient. We
recommend carrying out the process when the battery capacity indicated on the
charger or on a Leica Geosystems product deviates significantly form the actual
battery capacity available.

The permissible temperature range for charging is between 0°C to +40°C/+32°F
to +104°F. For optimal charging we recommend charging the batteries at a low
ambient temperature of +10°C to +20°C/+50°F to +68°F if possible.

It is normal for the battery to become warm during charging. Using the chargers
recommended by Leica Geosystems, it is not possible to charge the battery if
the temperature is too high.