Technical Data

TPS1200

201

Recording

Data can be recorded onto a CompactFlash card or into internal memory if fitted.

Laser plummet

Drives

Motorisation

Power

Type

Capacity [MB]

Number of measurements
per MB

CompactFlash card

64

256

1024

1750

Internal memory - optional •

64

1750

Type:

Visible red laser class 2

Location:

In standing axis of instrument

Accuracy:

Deviation from plumbline:
1.5 mm at 1.5 m instrument height

Diameter of laser point:

2.5 mm at 1.5 m instrument height

Type:

Endless horizontal and vertical drives

Maximum rotating speed: 50 gon/s

External supply voltage:

Nominal voltage 12.8 V DC, Range 11.5 V-13.5 V