LEICA TPS1200 User Manual
Page 207

Technical Data
TPS1200
207
The index n is calculated from the formula of Barrel and Sears, and is valid for:
Formulas
If the basic value of 60 % relative humidity as used by the EDM is retained, the
maximum possible error in the calculated atmospheric correction is 2 ppm,
2 mm/km.
visible red laser
1.0002859
670
Air pressure p:
1013.25 mbar
Air temperature t:
12 °C
Relative air humidity h:
60 %
Type
Index n
carrier wave [nm]
Formula for infrared EDM
ΔD
1
Atmospheric correction [ppm]
p
Air pressure [mbar]
t
Air temperature [°C]
h
Relative humidity [%]
α
x
(7.5 * t/(237.3 + t)) + 0.7857
Formula for visible red laser
1
273.15
TPS12_051
ΔD
1
= 283.05 -
0.29196 · p
· 10
x
4.126 · 10
-4
· h
-
TPS12_052
ΔD
1
= 285.93 -
0.29493 · p
· 10
x
4.126 · 10
-4
· h
-