6 powersearch ps – LEICA TPS1200 User Manual
Page 179

Technical Data
TPS1200
179
8.6
PowerSearch PS
Range
Measurements at the vertical limits of the fan or under unfavourable atmospheric
conditions may reduce the maximum range. (*aligned to the instrument optimal)
Shortest
measure distance
Searching
Characteristics
Reflector
Range PS
[m]
[ft]
Standard prism
200
650
360° prism
200*
650*
Mini prism
100
330
360° prism:
5 m
Typical search time:
<10 s
Default search area:
Hz: 400 gon, V: 40 gon
Definable search windows: Yes
Principle:
Digital signal processing
Type:
Infrared laser class 1