beautypg.com

Screen setting, Mask settings – Sanyo DSR-3016 User Manual

Page 86

background image

SCREEN SETTING

12

Use the jog dial to set T-2, and then turn the shuttle dial
clockwise.

Repeat this procedure to switch between T-1, T-2, T-3 and T-4.

13

Use the jog dial to move the cursor to 09, and then turn the
shuttle dial clockwise.

ON” flashes.

14

Use the jog dial to set “ OFF” , and then turn the shuttle dial
clockwise.

Repeat the above procedure to set cameras 10 (10) through to
16 (16) to “OFF”.

Note: Repeat steps 10 to 12 to set T-3 and T-4 as required.

15

Press the EXIT/OSD button.

The display returns to the normal screen.

Note:

Repeat the above procedure to make the settings for monitor 2.

For a 4-screen display, the timer function cannot be used for
automatic switching of screen images.

C

MASK settings

If you do not need camera images to be displayed on the monitor
screen, you can hide the images for individual cameras with a gray
pattern.

The DSR-3009 model can display only cameras 01 to 09.

Example 1: To prevent certain camera images from

being monitored for the period of time
set by the timer (TIMER A, B)

1

Set the timer setting for both TIMER A and TIMER B in the
TIME PERIOD SET menu. (See page 46.)

Set both TIMER A and TIMER B.


T-1


T-2


T-3


T-1
IN IN IN IN
01:ON 02:ON 03:ON 04:ON
05:ON 06:ON 07:ON 08:ON
09:OFF 10:OFF 11:OFF 12:OFF
13:OFF 14:OFF 15:OFF 16:OFF

EXIT/OSD

T-1

(6

00 - 12

00)

T-2

(12

00 - 16

00)

T-3

(16

00 - 24

00)

T-4

(24

00 - 6

00)


T-1
IN IN IN IN
01:OFF 02:OFF 03:OFF 04:OFF
05:OFF 06:OFF 07:OFF 08:OFF
09:OFF 10:OFF 11:OFF 12:OFF
13:OFF 14:OFF 15:OFF 16:OFF

SELECT WEEK OF TIME PERIOD
SEQUENCE TIME PERIOD A
MASK TIME PERIOD A
MOTION TIME PERIOD A

English

85