Head height alignment procedure – Integra CROMA24 User Manual
Page 60
60
Maintenance
Croma24 Service Manual
Figure 3-15. Upper Roller Adjustment.
Figure 3-15 shows how the motion (rapid drifting to the right or to
the left) of the roller determines which mounting screw should be
tightened in order to eliminate the motion of the roller so that the
roller stays in the center of the shaft and/or there is a gap when the
Lower Roller is rotated forward.
Head Height Alignment Procedure
Perform this procedure only when the encoder strip stabilizer has
been removed from the C-Bracket or whenever the alignment is in
question. The head height alignment procedure is to ensure that a
0.065” +/- 0.003” difference exists between the cartridge jet plate and
the Platen. See Figure 3-16.