Intelligent Motion Systems MDrive DSP-402 User Manual
Page 45
37
Part 2: DSP-402 Implementation
V2
V1
T0
T1 T2
T3
Velocity
Time
target_position X1
target_position X2
Figure 6.3: Single Set-Point Mode (Move After a Move) 6040h Bit 5=0
With change_set_immediately set to “1”
, symbolized by the clear area in Figure 6.2, the host advises the drive to apply
a new set-point immediately after reaching the last one. The relative timing of the other signals is unchanged. This behavior
causes the drive to already process the next set-point X
2
and to keep its velocity when it reaches the target_position X
1
at T
1
.
Then drive moves immediately to the already calculated next target_position X
2
.
V2
V1
T0
T1
T2
Velocity
Time
Second target_position
given - immediate response
target_position reached
Figure 6.4: Set of Setpoints (Move on a Move) 6040h Bit 5=1
Controlword (6040
h
) of Profile Position Mode
15 9
8
7
6
5
4
3 0
See 1.3
Halt
See 1.3
abs/rel
Change Set Immediately
New Set-Point
See 1.3
MSB
LSB
Bit
Name
Value
Description
4
New Set Point
0
Does not assume target position
1
Assume target position
5
Change Set
Immediately
0
Finish the actual positioning and then start the next positioning
1
Interrupt the actual positioning and start the next positioning
6
abs/rel
0
Target position is an absolute value
1
Target position is a relative value
8
Halt
0
Execute positioning
1
Stop motion with profile deceleration
Table 6.1: Profile Position Mode Bits of Controlword