Gss series hinge mount safety limit switch, Safety switches – Honeywell Switches and Sensors User Manual
Page 82
80
www.honeywell.com/sensing
GSS Series
Hinge Mount Safety
Limit Switch
The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution
to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not
supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the
NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset
position, closing the NC safety contacts.
The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-mounted from
the hinge point of the door. The tamper-resistant design and the positive opening contacts provide a higher
level of safety than the conventional spring-driven limit switches often used to monitor door position.
Low Energy Switching
In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface
directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers
a new gold plated contact version of the standard basic switch. This improves reliability of switching at low
currents and voltages by protecting the contact surfaces from contamination during operation or storage
prior to use.
Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain
environmental conditions, e.g. in the presence of moisture.
Low energy basic switches are rated as follows:
Operating Voltage U
e
1 Vdc to 60 Vdc or 1 Vac to 125 Vac
Operating Current I
e
1 mA to 50 mA
Example of catalog listing using a low energy basic switch - GSCB33S2.
Switching options:
GSC/D
GSE
Snap action contacts (1NC/1NO)
Slow action contacts (4NC)
Zb
22
21
14
13
11
12
21
22
31
32 4Y
41
42
Slow action contacts (1NC/1NO) BBM
Slow action contacts (2NC/2NO) BBM
Zb
21
13
22
14
11
12
21
22
33
34
2Y, 2X
43
44
Slow action contacts (2NC)
Slow action contacts (3NC/1NO) BBM
11
21
12
22
2Y
22
21
11
12
32
31
44
43
3Y, 1X
IEC 60947-5-1/EN 60947-5-1
Designation & Utilization
Rated operational current le (A)
VA
Category
at rated operational voltage Ue
rating
120 V
240 V
380 V
480 V
500 V
600 V
Make
Break
AC15
A600
6
3
1,9
1,5
1,4
1,2
7200
720
AC15
A300
6
3
-
-
-
-
7200
720
AC15
B300
3
1.5
-
-
-
-
3600
360
AC14
D300
0,6
0,3
-
-
-
-
432
72
125 V
250 V
DC13
Q300
0,55
0,27
69
69
DC13
R300
0,22
0,1
28
28
Electrical ratings:
SAFETY SWITCHES