Explosion proof switches, Roller lever, 2 conduit openings – Honeywell Switches and Sensors User Manual
Page 61: Maintained contact, Dpdt, preleaded with 0,91 m (3 ft) leadwire, Hermetically sealed
59
www.honeywell.com/sensing
Roller lever
Roller material:
Bronze
Operating force max. (OF):
Electrical rating A
Clockwise (CW)
2,22 N to 5,56 N (0.5 lb to 1.25 lb)
Counter clockwise (CCW)
11,1 N (2.5 lb)
Electrical rating B
3,34 N to 8,90 N (0.75 lb to 2.0 lb)
Pretravel max. (PT):
Electrical rating A, B
Clockwise (CW)
5,56 mm (0.219 in) 8°
Counter clockwise (CCW)
1,65 mm (0.065 in) 3.5°
Overtravel max. (OT):
Electrical rating A
Clockwise (CW)
90°
Counter clockwise (CCW)
25°
Electrical rating B
25°
Differential travel max. (DT):
Electrical rating A
0,18 mm (0.007 in) 0.25°
Electrical rating B
0,3 mm (0.012 in) 4°
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW
SPDT
A
EX-AR
CCW
SPDT
A
EX-AR30
CW/Class 1 Group B
SPDT
A
EX-AR800
CCW/Class 1 Group B
SPDT
A
EX-AR830
CW/High temperature
SPDT
A
EX-AR400
CW
SPDT
B
EXA-AR
CW/No mounting bracket
SPDT
B
EXA-AR62
CW/Nylon roller
SPDT
A
EX-AR182
CW/No mounting bracket
SPDT
A
EX-AR141
CW or CCW actuation, no return spring, low operating
force
Operating force max. (OF):
0,56 N (2 oz)
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW/CCW/No mounting bracket
SPDT
A
EX-AR16
Maintained contact
Operating force max. (OF):
3,34 N (0.75 lb)
Pretravel max. (PT):
5,56 mm (0.219 in) 8°
Overtravel max. (OT):
90°
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW
SPDT
A
EX-XR3
DPDT, Preleaded with 0,91 m (3 ft) leadwire
Operating force max. (OF):
Clockwise (CW)
2,22 N to 6,67 N (0.5 lb to 1.5 lb)
Counter clockwise (CCW)
12,2 N (2.75 lb)
Pretravel max. (PT):
6,35 mm (0.250 in)
Overtravel max. (OT):
25°
Differential travel max. (DT):
2,77 mm (0.109 in) 4°
Sealing:
NEMA Class 1 Group B
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW
DPDT
C
EXD-AR-3
CCW
DPDT
C
EXD-AR30-3
Hermetically sealed
Operating force max. (OF):
Clockwise (CW)
2,22 N to 6,67 N (0.5 lb to 1.5 lb)
Counter clockwise (CCW)
11,1 N (2.5 lb)
Pretravel max. (PT):
Clockwise (CW)
5,56 mm (0.219 in) 8°
Counter clockwise (CCW)
1,65 N (0.065 in) 3.5°
Overtravel max. (OT):
25°
Differential travel max. (DT):
0,64 mm (0.025 in)
Sealing:
NEMA Class 1 Group B
ACTUATION
CONTACT
ELECTRICAL RATING
REFERENCE
CW/3,2 m (10.5 ft) leadwire
SPDT
E
EXH-AR3
CCW/0,91 m (3 ft) leadwire
SPDT
E
EXH-AR33
CW/0,91 m (3 ft) leadwire
SPDT
E
EXH-AR7
2 Conduit openings
Operating force max. (OF):
Electrical rating A
2,22 N to 5,56 N (0.5 lb to 1.25 lb)
Electrical rating B
3,61 N to 8,90 N (0.8 lb to 2 lb)
Electrical rating C
2,22 N to 6,67 N (0.5 lb to 1.5 lb)
Pretravel max. (PT):
Electrical rating A, B
5,56 mm (0.219 in) 8°
Electrical rating C
6,35 mm (0.250 in)
Overtravel max. (OT):
Electrical rating A
90°
Electrical rating B, C
25°
Differential travel max. (DT):
Electrical rating A
0,18 mm (0.007 in) 0.25°
Electrical rating B
0,3 mm (0.012 in) 0.5°
Electrical rating C
2,77 mm (0.109 in) 4°
CONTACT
ELECTRICAL RATING
REFERENCE
DPDT
C
4EX1-3
SPDT
B
2EX1
SPDT
A
1EX1
EXPLOSION PROOF SWITCHES