Installation, Test and adjustment – Heath Zenith Replacement Motion Sensor SH-5407 User Manual
Page 2
-2-
598-1155-01
❒ Swing the sensor head towards the clamp
screw.
For eave mount only:
Controls
INSTALLATION
❒ Remove the existing light fi xture, if present.
These instructions show the sensor wired to fl ood-
lamps. The white sensor wire is neutral. The black
sensor wire is hot. The red wire is the switched
"hot" wire. The lighting load (500 W, 4.2A max) is
placed across the white and red wires.
❒ After screwing the sensor into the wall plate,
connect the junction box wires to the light control
wires by twisting together and securing with wire
connectors.
M
OUNT
THE
L
IGHT
❒ Follow the instructions that came with your light fi x-
ture for mounting and adjusting the light fi xture.
❒ Keep regular PAR-38 lamps at least 1" (25 mm)
from the sensor. Halogen lamps should be kept
at least 2" (51 mm) from the sensor.
Black to Black
White to White
Red Sensor Wire to
Black Lamp Wire
Optional: Connect additional load
across the white and red wires. Total
lighting load including lampheads on
fi xture must not exceed 500W (4.2A).
Junction
Box
Lamp Holders
For under eave installation, the sensor head
must be rotated as shown in the next two steps
for proper operation and to avoid the risk of elec-
trical shock.
❒ Rotate the sensor head clockwise 180° so
the controls face down.
Clamp Screw
Controls
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the
ball joint. Tighten the clamp screw when done.
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute calibration
period before it will detect motion. When
fi rst turned on, wait 1
1
/
2
minutes.
W
IRE
THE
L
IGHT
C
ONTROL
WARNING: Turn power off at circuit breaker
or fuse.