K. Lighting Instructions (IPI)
1. This appliance is equipped with an ignition
device which automatically lights the burner. 
DO NOT try to light the burner by hand.
2. Wait fi ve (5) minutes to clear out any gas.
Then smell for gas, including near the fl oor. If 
you smell gas, STOP! Follow “B” in the Safety 
Information located on the left side of this la-
bel. If you do not smell gas, go to next step.
3. To light the burner:
Equipped with wall switch: Turn ON/OFF switch 
to ON.
Equipped with remote or wall control: Press 
ON or FLAME button.
Equipped with thermostat: Set temperature to 
desired setting. 
4. If the appliance does not light after three tries,
call your service technician or gas supplier.
LIGHTING
INSTRUCTIONS (IPI)
TO TURN OFF
GAS TO APPLIANCE
1. Equipped with wall switch: Turn ON/OFF switch
to OFF.
Equipped with remote or wall control: Press 
OFF button.
Equipped with thermostat: Set temperature to 
lowest setting.
2. Service technician should turn off electric
power to the control when performing service.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion 
may result causing property damage, personal injury or loss of life.
CAUTION:
NOT FOR USE
WITH SOLID FUEL
WARNING:
593-913G
GAS
VALVE
For additional information on operating your
Hearth & Home Technologies fi replace, please refer to www.fi replaces.com.
A. This appliance is equipped with an
intermittent pilot ignition (IPI) device 
which automatically lights the burn-
er. DO NOT try to light the burner by 
hand.
B. BEFORE LIGHTING, smell all around
the appliance area for gas. Be sure to 
smell next to the fl oor because some 
gas is heavier than air and will settle 
on the fl oor.
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electric switch; do
not use any phone in your building.
DO NOT CONNECT LINE VOLT-
AGE (110/120 VAC OR 220/240 
VAC) TO THE CONTROL VALVE.
Improper installation, adjustment, al-
teration, service or maintenance can 
cause injury or property damage. Re-
fer to the owner’s information manual 
provided with this appliance.
This appliance needs fresh air for 
safe operation and must be installed 
so there are provisions for adequate 
combustion and ventilation air.
If not installed, operated, and main-
tained in accordance with the manufac-
turer’s instructions, this product could 
expose you to substances in fuel or 
fuel combustion which are known to the 
State of California to cause cancer, birth 
defects, or other reproductive harm.
Keep burner and control compartment 
clean. See installation and operating 
instructions accompanying appliance.
Hot while in operation. DO NOT touch. 
Keep children, clothing, furniture, gaso-
line and other liquids having fl ammable 
vapors away.
DO NOT operate the appliance with 
fi xed glass assembly removed, cracked 
or broken. Replacement of the fi xed 
glass assembly should be done by a 
licensed or qualifi ed service person.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the 
gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fi re department.
C. DO NOT use this appliance if any
part has been under water. Imme-
diately call a qualifi ed service tech-
nician to inspect the appliance and 
to replace any part of the control 
system and any gas control which 
has been under water.
For use with natural gas and propane. 
A conversion kit, as supplied by the 
manufacturer, shall be used to convert 
this appliance to the alternate fuel.
Also Certifi ed for Installation in a 
Bedroom or a Bedsitting Room.
For assistance or additional informa-
tion, consult a qualifi ed installer, ser-
vice agency or the gas supplier.
Final inspection by