1-4. WARNINGS AND
The controls monitor procedure problems and system failures
ERROR MESSAGES
with warnings and error codes. The display shows the
warning or error code, and an alarm sounds.
Pressing cancels most warnings and pressing any
control button stops most error code alarms. But there are
some exceptions (see below). The display shows the error
until the situation is corrected.
WARNINGS
DISPLAY
CAUSE
CORRECTION
“W-1”
Incoming supply voltage too low
Have voltage at plug and receptacle checked
“LOW
VOLTAGE”
“W-2”
Faulty components or connections
Have elements, connections, and contactors
“SLOW
checked
HEAT-UP”
“W-3”
Product loaded into frypot
Wait until shortening is at proper temperature
“WAS NOT
before lights
before loading product
READY”
“W-4”
Too much product
Do not overfill frypot
“SLOW
in frypot
COOKING”
“W-5
Product loaded into frypot
Wait until shortening is at proper temperature
“SLOW
before lights
before loading product
COOKING”
“W-6”
Faulty components or connections
Have elements, connections, and contactors
“SLOW
checked
COOKING”
“W-7”
Faulty components or connections
Have elements, connections, and contactors
“LOW AMPS”
checked
“W-9”
Product overcooked. (may
Discard product immediately
“DISCARD
appear after a “SLOW COOKING”
PRODUCT”
warning)
“OIL TOO
Didn’t allow shortening to drop
Cancel button stops this warning; once the
HOT”
to current product’s setpoint
shortening drops to setpoint temperature,
temperature
the alarm automatically stops