1-3. TROUBLESHOOTING(Continued)
PROBLEM
CAUSE CORRECTION
Heating of
• Low or improper
• Use a meter and check the receptacle
shortening too
voltage (elec. unit)
voltage against the data plate
slow
• Weak or burnt out
• Check heating elements per Heating
elements (elec. unit)
Elements Section
• Wire(s) loose
• Tighten
• Burnt or charred
• Replace wire and clean connectors
wire
connection
• Faulty contactor
• Check contactor per Heating Contactors
Section
Shortening
• Temperature probe
• Calibrate temperature probe if ± 10° off;
overheating
needs calibration
if more than
± 10° off, replace temperature
probe
• Mercury contactor
• Check mercury contactor for not opening;
stuck closed
replace if necessary (elec. unit)
• Bad control board
• Replace control board if heat indicator stays
on past ready temperature
Foaming or boiling
• Water in shortening • At end of cook cycle, drain shortening and
over of shortening
clean
• Improper or bad
• Use recommended shortening
shortening
• Improper filtering
• Refer to the Filtering the Shortening
Section in Operator’s Manual
• Improper rinsing
• Clean and rinse the frypot; then dry
after cleaning fryer
thoroughly
405