Henny Penny OFE-321 User Manual
Page 8
Model OFE-321,322
1-3. TROUBLESHOOTING
(Continued)
PROBLEM
CAUSE CORRECTION
Shortening will not
• Drain valve clogged • Open valve, force cleaning brush through
drain from frypot
with crumbs
drain
• Drain valve will not • Replace cotter pins in valve coupling
open by turning
handle
Filter motor runs
• Pump clogged
• Remove pump cover and clean
but pumps shortening
slowly
• Filter line connection • Tighten all filter line connections
loose
• Solidified shortening • Clear all filter lines of solidified shortening
in
lines
Filter switch on but
• Defective switch
• Check/replace switch per Filter Switch
motor does not run
Section
• Defective motor
• Check/replace motor
• Motor thermal
• Reset thermal switch on filter motor
protector
tripped
Motor hums but
• Clogged lines or
• Remove and clean pump and lines
will not pump
pump
• Replace pump seal, rotor and rollers
1-4
405