Error codes – Henny Penny OFE-321 User Manual
Page 11
Model OFE-321,322
3-5. WARNINGS AND
ERROR MESSAGES
(Continued)
ERROR CODES
DISPLAY CAUSE
CORRECTION
“E-41”
Memory scrambled; an individual
Turn the POWER switch off and back
“SYSTEM
product program may be scrambled:
on; if error code persists, have the
DATA LOST”
Ex: “E-41 -2- DATA LOST”; this
PC board checked or re-initialized
means product #2 program is
scrambled
“E-46”
Faulty eprom or PC board
Turn the POWER switch OFF and back
“DATA SAVE
on; if error code persists, have the
FAILED”
PC board checked or re-initialized
“E-47”
Failure of 12 volt DC supply
Turn the COOK/PUMP switch OFF and back
“ANALOG
on the I/O board
to COOK; if the and DO NOT
SYSTEM
OR 12 VOLT
light up when the 8888’s are displayed, have the
FAILED”
I/O board replaced
Amp sensors plugged in backwards
Have positions of amp sensors checked
Faulty PC board
Have control panel replaced
“E-48”
Failure of 12 volt DC supply
Turn the COOK/PUMP switch OFF and back
INPUT
on the I/O board
to COOK; if the and DO NOT
SYSTEM
ERROR”
light up when the 8888’s are displayed, have the
I/O board replaced
Faulty PC board
Have control panel replaced
“E-70”
Faulty POWER switch
Have POWER switch checked, along
“PWR SW
or switch wiring; faulty
with its wiring; have I/O board checked
OR WIRES
I/O
board
FAILED”
“E-92”
Blown 24 volt controller fuse, or
Have the 14-pin cable connector checked or
“24 VOLT
bad 14-pin cable connection
have the fryer checked for a short to ground
FUSE”
in components such as the drain switch,
or high limit and wiring
405