Henny Penny OFE-321 User Manual
Page 23
![background image](/manuals/93626/23/background.png)
Model OFE-321,322
9. Insert new 425 degree high limit, part no. 60241 and
replace
screws.
2-11
10. Uncoil capillary tube, starting at control, and insert through
pot
fitting.
To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must NEVER be in such a position
where it could accidentally touch the electrical power
terminals.
11. Carefully bend the capillary bulb and tube toward bulb holder
on
heating
elements.
12. Slip capillary bulb into bulb holder on heating elements.
Pull excess capillary line from pot and tighten nut into frypot
wall.
Be sure capillary bulb of high limit is located behind
capillary bulb of thermostat. Both capillary bulbs
and bulb holders should be positioned as not to interfere
with basket or when cleaning the frypot wall, or damage to
capillary
tube
could
result.
13. With excess capillary line pulled out, tighten smaller nut hand
tight, then ¼ turn with wrench.
14. Replace front panel.
15. Refill with shortening.
409
2-12
2-12. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)