Henny Penny OFE-321 User Manual
Page 10
Model OFE-321,322
1-4. WARNINGS AND
ERROR MESSAGES
(Continued)
ERROR CODES
DISPLAY
CAUSE
CORRECTION
“E-4”
PC board too hot
Check ventilation louvers on side of fryer
“CPU TOO
for obstructions; if louvers are clear,
HOT”
have PC board checked
“E-5”
Controls sensing 405°F
Have heat components and temperature
“FRYER TOO
or above
probe checked
HOT”
“E-6”
(
A
or
B
)
Faulty temperature probe or
Have temperature probe and connection
“FRYER
connection
checked
TEMP
SENSOR
FAILED”
“E-10”
Shortening temperature too hot,
Reset high limit (see Operating Components
“HIGH LIMIT
drain valve opened while heat was
Section); check shortening temperature for
TRIPPED”
on, or faulty high limit
overheating; have heat components checked
if high limit continues to trip.
“E-15”
Drain is open or faulty microswitch
Close drain; have drain microswitch
“DRAIN IS
checked if error code persists
OPEN”
“E-25”
Wrong or faulty elements or wiring
Have electrical supply, wiring, and elements
“HEAT AMPS
problem
checked
WERE TOO
HIGH”
Because of the seriousness of this
error code, turn the POWER switch
off and back on to cancel
“E-26”
Faulty contactors or PC board
Have the contactors and PC board checked
“HEAT AMPS
ARE LOCKED
ON”
This error code could be displayed
even with the POWER switch turned
off. Unplug fryer or shut off the
wall circuit breaker to disconnect
electrical power to fryer.
1-6
405