Troubleshooting

22

311051D

Spray Pattern Troubleshooting

Problem

Cause

Solution

Fluid flow is fluttering while spraying. Fluid nozzle is not tight enough.

O-ring (36) is missing or damaged.

Fluid filter is clogged.

Tighten fluid nozzle to 60 in-lb (6.8
N•m).

Replace o-ring.

Check fluid filter.

Fluid flow fades while spraying high
viscosity fluids.

Fluid pressure is too low, causing
fluid flow to reduce when gun is ele-
vated.

Raise fluid pressure at source or use
a smaller fluid nozzle.

Pattern becomes off-set of heavy on
ends.

Air cap horn holes plugged or dam-
aged.

Clean air cap horn holes with
non-metallic item such as a toothpick,
or replace air cap.

Gun fluid pressure is too high with
gun triggered.

Using needle/nozzle kit with too small
orifice.

Use needle/nozzle kit with larger ori-
fice.

Fluid system will not operate at low
enough fluid pressure [below 10 psi
(70 kPa, 0.7 bar)].

There is no fluid regulator, or air reg-
ulator on pressure pot is not sensitive
enough at low pressures.

Add low pressure fluid regulator, or
add more sensitive low pressure air
regulator on pressure pot.