Service

24

311051D

13. Remove all o-rings from the piston (3) and stems

(T). Check that the stems are solidly in place. If they
are loose, replace the entire piston assembly (3).

14. Perform the following applicable step:

a.

Non-circulating guns: Remove the fluid outlet

port plug (19), and gasket (22) from the fluid

housing (2). Remove the o-ring (21) and backup

(20) from the plug.

b.

Circulating guns: Remove the gasket (22) from

the fluid housing (2).

15. Clean all parts and replace any worn parts. When

assembling, lubricate the threads with anti-seize
lubricant.

F

IG

. 21

SERVICE NOTES:

Torque to 35-45 in-lb (4.0-5.1 N•m)

Lubricate threads with anti-seize lubricant

Lubricate with light-weight oil

Tighten cap (4) until it bottoms out

Apply semi-permanent anaerobic sealant

Torque to 4-5 in-lb (0.45-0.57 N•m)

Torque to 95-105 in-lb (10.7-11.8 N•m)

Apply semi-permanent anaerobic sealant to two
threads at end of needle shaft.