Setup

14

311051D

Flush Spray Gun

Before running any paint through the spray gun:

1.

Flush the gun with a solvent that is compatible with
the fluid to be sprayed, using the lowest possible
fluid pressure and a grounded metal container.

2.

Perform Pressure Relief Procedure; see page 17.

Position Air Cap

Air caps are factory-set with the alignment pin (A) set to
a vertical spray pattern. To change the air cap to a hori-
zontal spray pattern, use a needle nos pliers to unscrew
the alignment pin (A) and relocate it to the horizontal
spray pattern hole. When relocating the pin use low
strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3
N•m). Do not overtighten. Refer to F

IG

. 11.

F

IG

. 10: Manifold Ports

Side Mounted Manifold Ports

Bottom Mounted Manifold Ports

FAN

ATOM

CYL

FAN

ATOM

CYL

KEY
N Cylinder Air Inlet: accepts 1/4 in. (6.3 mm) O.D. tubing
P Atomization Air Inlet: 3/8 in, (9.5 mm) O.D. tubing
R Fan Air Inlet: 3/8 in. (9.5 mm) O.D, tubing
S Fluid Inlet: 1/4 npsm
T Fluid Outlet (circulating gun only): 1/4 npsm

N

S (or T)

T (or S)

R

P

N

S (or T)

T (or S)

R

P

TI8096a

TI8097a

F

IG

. 11: Position Air Cap

Vertical Pattern

Horizontal Pattern

TI8171a

TI8170a

A

TI8172a