Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. X • 6/13

9

Fireplace Structure

Noncombustible mat’l

Mantel

25 in.

(635 mm)

minimum

6 in.

(151 mm)

minimum - one side only.

Alcove installations require

14 in. (356 mm) from each side

of the firebox opening.

82 in.

(2083 mm)

minimum

height

Additional Structure

or Sidewall

Ceiling or

Overhang

12 in. (305 mm)
max. combustible
mantel depth

49-1/2 in.

(1257 mm)

minimum

16 in.

(406 mm)

deep non-combustible

hearth extension recommended

when floor in front is combustible.

Figure 3.3

Clearances

WARNING! Risk of Fire!

Comply with all minimum
clearances to combustibles as
specifi ed. Framing or fi nish-
ing material closer than the
minimums listed must be con-
structed entirely of non-com-
bustible materials (i.e., steel
studs, concrete board, etc).