beautypg.com

Front back – Hearth and Home Technologies CARODG36I User Manual

Page 7

background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. X • 6/13

7

6 in.

6 in.

6 in. min.

36 in. min.

cement

board from

the top of the

firebox

opening

36 in. min.

noncombustible

finishing

material

82 in.

(2083 mm)

floor to ceiling

0 in.

Combustible Object

36 in.

(914 mm)

Front

Back

Note: If this surface is
inside the building’s
warm air envelope...

...then this surface
must be an exterior
wall system.

57 in.

(1448 mm)

minimum

1 1/2 in.

(38 mm)

56 in.

(1422 mm)

79 1/4 in.

(2013 mm)

17 in.

(432 mm)

48 in.

(1219 mm)

1 1/2 in.

(38 mm)

1 1/2 in.

(38 mm)

Control

Box

ControlBox

42 1/2 in.

(1080 mm)

minimum

header height

42 1/2 in.

(1080 mm)

minimum

header height

68 1/2 in.

(1740 mm)

minimum

to top of cement

board

17 in.

(432 mm)

Flashing

Cement Board

Control box

MUST be

relocated!

Exterior

Interior

11 1/2 in.

(292 mm)

minimum

8-1/4 in.

(210 mm)

10-5/8 in.

(270 mm)

48 in.

(1219 mm)

48 in.

(1219 mm)

Framing

36 in. minimum

(889 mm)

from appliance front

Side clearances can be zero at framing,

up to 6 inches deep

Side clearances can be zero at framing,

up to 6 inches deep

6 in.

6 in.

36 in. minimum

(889 mm)

from appliance front

Note: For actual appliance
dimensions refer to Section 12.

Figure 3.1

Appliance Locations and Framing Dimensions - CARODG36I, CARODG36IL

NOTICE:

Vinyl siding must

not be placed between the
fireplace opening and the
ceiling/overhang.

NOTICE:

Flash the perimeter of the fi replace, corners and

the fi replace face in a manner consistent with regional
practices as required to prevent water penetration around
the fi replace or manage water that may penetrate the
fi replace. See Section 3.D. for more information regarding
wall and enclosure construction.

E. Clearances and Framing Dimensions

CARODG36I, CARODG36IL

This manual is related to the following products: