beautypg.com

Finishing, Warning, A. mantel projections – Hearth and Home Technologies Cyclone-Cust User Manual

Page 30: B. facing material

background image

Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08

30

A. Mantel Projections

This appliance is approved to be installed with a clearance
to the ceiling and/or other projections of 34-3/8 inch
minimum from the top of the fi replace (see Figure 11.1).

11

11

Finishing

B. Facing Material

Fire Risk.

Finish all edges and fronts to clearances and
specifi cations listed in manual.

• Install combustible materials only up to specified

clearances on top, front and side.

• Seal joints between the fi nished wall and appliance top

and sides using only a 300º F minimum sealant.

Figure 11.1 Clearances to mantels or other combustibles

above appliance

Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
• Modifying or covering grilles could cause
temperature rise and fi re hazard.

Finishing materials must not interfere with:
• Air fl ow through grilles or louvers.

• Operation of louvers or doors.

• Access for service.

WARNING

WARNING

Figure 11.2 Facing Diagram

Sheetrock or other fi nishing materials can be brought to
within 0 inches on the sides and bottom.

Finishing materials for the top of the fi replace base must
be noncombustible and removable for access to controls.
All clearances must be maintained (see Figure 11.3).

NON-COMBUSTIBLE

SEALANT MATERIAL

COMBUSTIBLE

ON SIDES

0 IN.

0 IN.

Figure 11.3

Ø 9-1/8 in. MIN.

OPENING

1/2 in.

MATERIAL MUST BE
NON-COMBUSTIBLE

AND REMOVABLE

TOP MUST

MAINTAIN 1/2 in.

CLEARANCE

SLIP

SECTION

COMBUSTIBLE

MATERIAL

41-3/8 in.

(+0 to -1/2 in.)

34-3/8 in.

TO CEILING

AND/OR MANTEL

FIRESTOP

FRAMING

MEMBER

GLASS

TUBE

TOP