Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08

13

H

T

V

T

Figure 5.3

Figure 5.4

D. Vent Diagrams

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

H

T

H

1

H

2

V

T

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling fi restops.

• ALWAYS maintain specifi ed clearances around venting and fi restop systems.

• Install wall shield and ceiling fi restops as specifi ed.

Failure to keep insulation or other material away from vent pipe may cause fi re.

WARNING

V

T

Min.

H

T

Max.

2 ft.

2 ft.

3 ft.

6 ft.

4 ft.

10 ft.

5 ft.

15 ft.

V

T

+ H

T

= 40 ft. Max

NOTE: A minimum of 2 feet before
the fi rst 90º elbow can be achieved by
using a 12 inch section of DVP and the
(cyclone-12slip) slip section.

H

1

H

2

V

T

Min.

H

T

Max.

*

*

2 ft.

2 ft.

*

*

3 ft.

6 ft.

*

*

4 ft.

10 ft.

*

*

5 ft.

15 ft.

V

T

+ H

T

= 40 ft. Max.

*No specifi c restrictions on this value

EXCEPT V

T

+ HT cannot exceed 40 ft. Max.