Hearth and Home Technologies Cyclone-Cust User Manual
Page 19

Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
19
7
7
Appliance Preparation
A. Securing and Leveling the Appliance
Figure 7.1 Proper positioning, leveling and securing of an
appliance
SCREW HOLES PROVIDED FOR SECURING
Fire Risk.
• ALWAYS maintain specifi ed
clearances around the appliance.
• Do NOT notch into the framing around the appliance spacers.
Failure to keep insulation, framing or other material away from
the appliance may cause fi re.
Fire Risk.
• Prevent contact with sagging, loose insulation.
• Do NOT install against combustible materials
such as exposed insulation, plastic and insulation
backer.
WARNING
WARNING
The diagram shows how to properly position, level, and
secure the appliance (see Figure 7.1). Holes are provided
to secure the appliance to the framing members with
screws.
• Horizontal venting - refer to Vent Clearances and Framing
(Section 6) for hole location.
• Place the appliance into position.
• Level the appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use
wood shims.
• Secure the appliance to the framing by using nails
or screws through the holes in the base plate of the
appliance.