Test and adjustment, Specifications – Heath Zenith Motion Sensor Light Control SH-5411 User Manual
Page 4

4
598-1157-05
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
❒
Loosen the clamp screw in the
sensor ball joint and gently 
rotate the sensor.
❒
Walk through the coverage
area noting where you are 
when the lights turn on (also, 
the LED will flash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 
Keep the sensor at
least 1" (2.5 cm) away from 
the lamps.
❒
Adjust the RANGE as needed.
RANGE set too high may 
increase false triggering.
❒
Secure the sensor head by 
tightening the clamp screw. 
Do not overtighten the screw.
❒
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up to 240 Watt Maximum Tung-
sten [Up to 120 Watt maximum 
each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL 
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features 
in products previously sold.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned 
on, wait 1 
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat 
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
•
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
Clamp 
Screw
Ball 
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Least Sensitive
Most Sensitive
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Maximum Range
Maximum
Coverage Angle
RANGE
10 5 1 TEST
ON-TIME
MAX
MIN
RANGE
ON-TIME
10 5 1 TEST
MINUTES
MIN
MAX
NOTE: Meets the ENERGY STAR
®
guidelines when used
with 120 W Max bulbs.
❒
Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control 
to the TEST position.
Motion
Motion
180°
Sensor
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming 
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.