beautypg.com

HP VA7410 User Manual

Page 3

background image

Chapter 4

Peripherals and Accessories

HP e3000 Business Servers Configuration Guide – Effective 1/04

4-93

Information Subject to Change

The VA7110 is designed to communicate with multiple hosts and multiple systems, otherwise known as

heterogeneous support. Any combination of the supported operating systems—HP-UX, Windows NT, Solaris,

AiX, NetWare, Windows 2000, MPE/iX, and Linux can be used. Two different protocols, or host port behaviors,

are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and

another for HP-UX. The Windows/Linux host port behaviors must be configured in the array for

communication to take place with any or all four supported operating systems on a controller. When changing

the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX.

The VA7110 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis.

Each LUN operates appropriately given the description of the operating system requirements.

The VA7110 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk

array capacity reserved to perform a rebuild. This feature requires the use of one or two additional disk units

in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks

fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which

improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the

disk array performance until the storage is needed.

Each enclosure will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The

array requires three EIA units (3U) in height (per enclosure), which allows ten units to be placed in a standard

1.6-meter rack. The rear of the EIA rack mountable chassis also includes two 1-GB fibre channel controllers,

dual power supplies and dual fan modules. The redundant power supply and fan components are combined

into a single module. All modules are hot swappable.

The array can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface

with 1 or 2 gigabit per second transfer rates (the default setting is 1 gigabit). It can be ordered in

factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the

HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.

The VA7110 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and

resolution capability securely delivers remote reactive services that quickly resolve problems, proactive

service that anticipate and prevent downtime due to computing issues, and value-added services to help

monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is

required. It is included with the VA for the first year.

The revision numbering for firmware for the VA7110 has changed. The revision numbering now consists of a

string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123”

represents the following:
• “X” is a single capital letter (A – Z) designating the platform

• “1” is a single number or capital letter (0-9, A-Z) designating a major FW revision

• “2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision

• “3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision


VA7410 Overview

The HP StorageWorks Virtual Array 7410 is a Fibre Channel (FC) disk storage system that supports from ten to

105 disk drives. The VA7410 has two FC ports on each controller. The VA7410 is comprised of two types of

enclosures, each three EIA units high: the virtual array controller enclosure (A6183A/AZ) and the disk system

enclosure (A6214A/AZ) also referred to as the disk enclosure or the JBOD (Just a Bunch Of Disks) enclosure.

In addition, pre-defined SKUs are available to facilitate integrated arrays. The array consists of one controller

enclosure and one to six disk enclosures, with scalable capacities from 181 GB to 1.90 TB (using 18-GB 15K

rpm disk drives), 364 GB to 3.82 TB (using 36-GB 10K rpm disk drives), 720 GB to 7.67 TB (using 73-GB 10K

rpm disk drives), or 1.46 TB to 15.33 TB (using 146-GB 10K rpm disk drives). Capacities and spindle speeds can

also be mixed throughout the array.

This manual is related to the following products: