beautypg.com

Installation – Heath Zenith BL-1800 User Manual

Page 2

background image

2

598-1321-01

INSTALLATION

For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about
8 feet (2.4 m) above the ground.

W

ire

the

L

ight

C

ontroL

For eave mount only:

Wall Mount

Eave Mount

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

Align the light control cover plate and the junction

box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor

plate (not included) was used,

caulk the wall plate

and mounting surface with silicone.

M

ount

the

L

ight

C

ontroL

Rotate the sensor head towards the clamp screw

joint.

Then rotate the sensor head clockwise 180° so the

controls face down.

Control Switch

Joint Clamp

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood-
lamps, do not overtighten.

Keep lamps at
least 1" (25 mm)
from the sensor.

Avoid water damage and
electrical shock - keep lamp
holders below horizontal.

Lock nuts

Black to

Black

White to

White

Gasket

Drill the holes needed
to mount the backplate
to the junction box.

Remove the existing light fixture.

Route the light control’s wires through the large

gasket hole.

Connect the junction box wires to the light control

wires. Twist together and secure with a wire
connector.

WARNING: Turn power off at the fuse or circuit

breaker.