WARNING
Storage in or on appliance – Flammable materials should
not be stored in or near the appliance.
▶
DO NOT store or use corrosive chemicals, vapors,
flammables, or nonfood products in or near this appli-
ance. It is specifically designed for use when heating or
cooking food. The use of corrosive chemicals while
heating or cleaning will damage the appliance and
could result in injury.
1.4 Gas requirements
Natural gas w.c.
Minimum
7" (17.4 mbar)
Maximum
14" (34.9 mbar)
LP gas w.c.
Minimum
11" (27.4 mbar)
Maximum
14" (34.9 mbar)
¡
A manual valve must be installed in an accessible loca-
tion in the gas piping external to the appliance for the
purpose of turning on or shutting off gas to the appli-
ance.
¡
In the event a burner goes out and gas escapes, open
a window or a door. DO NOT attempt to use the appli-
ance until the gas has had time to dissipate. Wait at
least 5 minutes before using the appliance.
¡
The maximum depth of cabinets installed above cook-
ing surface must be 13'' (330 mm).
For Massachusetts installations:
¡
Installation must be performed by a qualified or li-
censed contractor, plumber or gas fitter qualified or li-
censed by the state, province or region where this ap-
pliance is being installed.
¡
Shut-off valve must be a “T” handle gas cock.
¡
Flexible gas connector must not be longer than 36"
(914 mm).
1.5 State of California Proposition 65
Warnings
This product may contain a chemical known to the State
of California, which can cause cancer or reproductive
harm. Therefore, the packaging of your product may bear
the following label as required by California:
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS