Christie DWU1075-GS 10,875-Lumen WUXGA 1DLP Laser Phosphor Projector with BoldColor Technology (No Lens) User Manual
Page 56

Operation
GS Series 1075 User Manual
56
020-001225-04 Rev. 1 (10-2018)
Network
Factory Reset
Executes a network factory reset. Network
settings may be reset to the following default
values.
Projector Name = Christie@ + Serial Number
Show Network Messages = ON
LAN settings:
• Manual
• IP Address = 192.168.0.100
• Subnet Mask = 255.255.255.0
• Default Gateway = 192.168.0.100
WLAN settings:
• Enable
• Start IP = 192.168.1.100
• End IP = 192.168.1.120
• Subnet Mask = 255.255.255.0
• Default Gateway = 192.168.1.100
SNMP settings:
• SNMP Read Community = private
• Trap IP Address = 0.0.0.0
• SMTP IP Address = 0.0.0.0
• All other settings are cleared or blanked
Trap Configuration:
• All items = SNMP Trap + Email
LAN Setting
Panel
Sets whether the projector must obtain an
automatically assigned IP address through
DHCP or if the user sets the address manually.
For the TCP/IP setting, enter the IP address,
netmask, and default gateway address.
WLAN Setting
Panel
Enables or disables the wireless LAN of the
projector.
Enter the IP address range, netmask, and
default gateway for the wireless LAN.
SNMP Panel
Provides network administrators with a
common way to manage their network devices
from a single remote location.
Administrators can use the Simple Network
Management Protocol (SNMP) interface to
query a number of devices to see their current
status or configuration.
Operators can change configuration values and
configure trap notifications to be sent when
certain events occur (for example, loss of
signal, power state change, and so on).
Emails are sent to the mail server configured in
the projector settings. Up to two user email
accounts can be selected. Important
information regarding the event is located in
the body content of the email.
SNMP Traps are notifications sent from the
projector and are only received by a trap
receiver (MIB Browser) in the computer.
• SNMP Read Community (default setting:
private)—Plain text password that must also
be entered in the MIB browser. This
password allows various settings in the
projector to be queried.
• SNMP Location (default setting: blank)—Use
as a description to where a projector is
located in a building. SNMP emails sent
specify this location.
• Trap IP Address (default setting: 0.0.0.0)—
Fill in this field with the IP address of the
computer, on which you want to view
received traps from the projector.
• Trap Email 1/2 (default setting: Blank)—Set
the Trap Email 1 and 2 to an email address
configured under the mail server entered in
the SMTP Server IP Address field.
• Email from Address (default setting:
blank)—Set the name of the source of the
SNMP emails.
• SMTP Server IP Address (default setting:
0.0.0.0)—Enter the IP address of the mail
server.
Panel
Description
Fields