Ils connection, Mounting, Orientation – CHAUVET DJ GigBAR Move + ILS 5-in-1 Lighting System with Moving Heads, Pars, Derbys, Strobe, and Laser Effects User Manual
Page 17: Rigging, Proper usage, Setup ils connection

Page 11
GigBAR MOVE + ILS User Manual Rev. 3
Setup
ILS Connection
ILS (Integrated Lighting System) provides 4 modes that synchronize with the GigBAR MOVE + ILS: Modes
1 and 3 synchronize with side 1 of the GigBAR MOVE + ILS, whereas modes 2 and 4 synchronize with
side 2 of the GigBAR MOVE + ILS. When linked, effects will sync with the most similar effect on the
selected side of the GigBAR MOVE + ILS: Kinta effects will sync with one of the kintas, moving heads will
sync with one of the moving heads, and wash effects will sync with one of the pars. Laser effects will sync
with the laser, and strobe effects will sync with the strobe effects regardless of ILS mode.
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the
Orientation
The GigBAR MOVE + ILS must be mounted in a position that includes planning for safe laser usage. In
addition, make sure adequate ventilation is provided around the product.
Rigging
•
Before deciding on a location for the product, always make sure there is easy access to the product
for maintenance and programming.
•
Make sure that the structure or surface onto which you are mounting the product can support the
•
When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, such as an elevated platform or a truss.
•
When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
•
The bracket adjustment knobs allow for directional adjustment when aiming the product to the desired
angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs.
Mounting Diagram
Proper Usage
This product is for overhead mounting only. For safety purposes, Chauvet recommends mounting lighting
effect products on steady elevated platforms or sturdy overhead supports using suitable hanging clamps.
In all cases, use safety cables. Obtain appropriate mounting hardware from your lighting vendor.
International laser safety regulations require that laser products must be operated in the fashion
illustrated below, with a minimum of 3 meters (9.8 ft) of vertical separation between the floor and
the lowest laser light. Additionally, 3 meters of horizontal separation is required between laser light
and audience or other public spaces.
CAUTION! Use of controls, adjustments, or procedures other than THOSE specified IN
THIS USER MANUAL may result in hazardous radiation exposure.
Safety cable
(such as
CH-05
from Chauvet)
Tripod mounting
insertion point
3 meters