beautypg.com

RF-Links 120mW Wideband Microwave Amplifier (50 MHz-6 GHz) User Manual

Page 2

background image

Parameter

Min.

Typ.

Max.

Unit

Condition

Small Signal Gain

19.0

20.5

22.0

dB

850 MHz

18.3

19.0

21.5

dB

1950 MHz

14.5

15.5

17.5

dB

6000 MHz

Output Power at 1 dB Compression

20.5

dBm

850 MHz

19.0

20.0

dBm

1950 MHz

Third Order Intercept Point

38.5

dBm

850 MHz

33.0

35.0

dBm

1950 MHz

Bandwidth

3000

MHz

Min. 10 dB return loss (typ.)

Input Return Loss

10.0

13.0

dB

1950 MHz

Output Return Loss

10.0

14.0

dB

1950 MHz

Reverse Isolation

23.3

dB

1950 MHz

Noise Figure

3.9

4.9

dB

1950 MHz

Device Operating Voltage

4.75

5.0

5.25

V

Device Operating Current

60.0

75.0

92.0

mA

Thermal Resistance

69.9

°C/W

junction - lead

Typical Performance at Key Operating Frequencies (0.5GHz to 3.5GHz Application Circuit)

Specification

Parameter

Min.

Typ.

Max.

Unit

Condition

21.1

dB

50 MHz

20.9

dB

100 MHz

20.8

dB

200 MHz

20.8

dB

500 MHz

20.8

dB

850 MHz

20.1

dB

1950 MHz

19.8

dB

2500 MHz

18.7

dB

3500 MHz

Small Signal Gain

17.8

dB

4000 MHz

36

dBm

50 MHz

37.8

dBm

100 MHz

37.5

dBm

200 MHz

38.6

dBm

500 MHz

39.2

dBm

850 MHz

34.9

dBm

1950 MHz

32.8

dBm

2500 MHz

Output Third Order Intercept Point

29.4

dBm

3500 MHz