Controller Tag
Data Type
Description
PassCnt
INT
This value is incremented each time a complete
program cycle occurs in the module.
ProductVersion
INT
Product version
ProductCode
INT[2]
Product code
BlockStats.Read
INT
Total number of read blocks transferred from the
module to the processor
BlockStats.Write
INT
Total number of write blocks transferred from the
processor to the module
BlockStats.Parse
INT
Total number of blocks successfully parsed that were
received from the processor
BlockStats.Cmd
INT
Total number of Command Control blocks received
from the processor
BlockStats.Err
INT
Total number of block errors recognized by the module
CmdBits[x]
INT
Displays enabled or disabled status of all 16
commands in the Client x Command List for each
Client
ClientStatsTrigger
BOOL
Initiates request for Client Status block from module
when set to 1
ClientID
INT
Specifies Client (0-15) to request status data from
ClientStatus[x].CmdReq
INT
Total number of command list requests sent from
Client
ClientStatus[x].CmdResp
INT
Total number of command list responses received by
Client
ClientStatus[x].CmdErr
INT
This value is incremented each time an error message
is received from a remote unit or a local error is
generated for a command.
ClientStatus[x].Requests
INT
Not used
ClientStatus[x].Responses
INT
Not used
ClientStatus[x].ErrSent
INT
Not used
ClientStatus[x].ErrRec
INT
Not used
ClientStatus[x].CfgErrWord
INT
Configuration Error Word - This word contains a
bitmap that indicates general module configuration
errors.
ClientStatus[x].CurErr
INT
Most recent error code recorded for the Client
ClientStatus[x].LastErr
INT
Previous most recent error code recorded for the
Client
CmdErrorList[x]
INT
Command error code for each command (0-15) on the