5 poe schedule – PLANET WGSD-10020 User Manual
Page 311

User’s Manual of WGSD-10020 Series
311
The page includes the following fields:
Object
Description
• Current Power
Consumption
Show the total watts usage of PoE Switch.
• Total Power Reserved
Shows how much the total power be reserved for all PDs.
• Temperature 1
Display the current operating temperature of PoE chip unit 1.
The unit 1 is in charge of PoE Port-1~Port-12
• Temperature 2
Display the current operating temperature of PoE chip unit 2.
The unit 1 is in charge of PoE Port-13~Port-24
•
Local Port
This is the logical port number for this row.
•
PD Class
Display the class of the PD attached to the port, as established by the classification
process.
Class 0 is the default for PDs. The PD is classified based on power. The
classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes. A PD shall return Class 0 to 3 in accordance with
the maximum power draw as specified by
Table 4-16-1
.
•
Power Used [W]
The Power Used shows how much power the PD currently is using.
•
Current Used [mA]
The Power Used shows how much current the PD currently is using.
• Priority
The Priority shows the port's priority configured by the user.
• Port Status
The Port Status shows the port's status.
• Total
Show the total watts usage of all PDs.
Buttons
Auto-refresh
:
Check this box to enable an automatic refresh of the page at regular intervals.
: Click to refresh the page immediately.
4.16.5 PoE Schedule
This page allows the user to define PoE schedule. The screen in Figure
4-16-5
appears.