Amprobe – Amprobe DMIII-Multitest Power-Quality-Recorder User Manual
Page 5

AMPROBE
DMIII MULTITEST
EN-3
16.1.
Continuity Test On Protective Conductors ............................................................................................................. 82
16.2.
Check of the Circuit Separation ............................................................................................................................. 83
16.3.
Measurement Of Floor Insulation Resistance In Medical Rooms Cei 64-4 ............................................................ 86
16.4.
Ground Resistance Measurement ......................................................................................................................... 88
16.5.
Ground Resistivity Measurement ........................................................................................................................... 89
16.6.
Voltage Anomalies (Voltage Sag and Surge) ......................................................................................................... 91
16.7.
Voltage and current Harmonics ............................................................................................................................. 91
16.7.1.
Theory ..............................................................................................................................................................................91
16.7.2.
Limit values for harmonics ...............................................................................................................................................93
16.7.3.
Presence of harmonics: causes .......................................................................................................................................93
16.7.4.
Presence of harmonics: consequences ...........................................................................................................................94
16.8.
Power and Power Factor definition ........................................................................................................................ 94
16.8.1.
Conventions on powers and power factors ......................................................................................................................96
16.8.2.
3 Phase 3 Wire System ...................................................................................................................................................97
16.9.
Measuring Method: outlines ................................................................................................................................... 98
16.9.1.
Integration periods ...........................................................................................................................................................98
16.9.2.
Power factor calculations .................................................................................................................................................98
16.9.3.
Voltage Anomalies and Periods Analysis comparison .....................................................................................................98
17. APPENDIX 1 – MESSAGES DISPLAYED ................................................................................................100
18. APPENDIX 2 – RECORDABLE PARAMETERS: SYMBOLS ...................................................................101
Release EN 1.00 of the 31/06/2005