10-19
Troubleshooting > Responding to Messages
M
Message
Checkpoints
Corrective Actions
Reference
Page
Machine failure.
Is the expansion memory
replaced?
The memory is not installed correctly.
Reinstall the memory.
—
Internal error has occurred. Make a note
of the error code displayed on the touch
panel, and contact your Service
Representative.
—
Maximum number of scanned
pages.
Is the acceptable scanning count
exceeded?
Only one copy of the scanned pages is
available.
Press [Continue] to print, send or store
the scanned pages.
Press [Cancel] to cancel printing,
sending or storing.
—
Memory is full.*
*
When Auto Error Clear is set to [On], processing resumes automatically after a set amount of time elapses.
—
The process cannot be performed due
to insufficient memory. If only [End] is
available, press [End]. The job will be
canceled.
The machine may reproduce the same
originals by arranging the following
settings:
- Decrease [Image Quality] of [File
Format].
Furthermore, the machine may
reproduce the same originals by
arranging the following settings:
- Select [Normal] of Main Memory in
System Menu.
NOTE: Before changing the Main
Memory setting, contact your
administrator.
—
Unable to continue the job as the
memory is used up. Press [Continue] to
print the scanned pages. The print job
cannot be processed completely. Press
[Cancel] to cancel the job.
The machine may reproduce the same
originals by arranging the following
settings:
- Select [On] of RAM Disk Setting in
System Menu, and then decrease the
RAM disk size.
- Select [Printer Priority] of Main
Memory in System Menu.
NOTE: Before changing the RAM
Disk Setting or Main Memory
setting, contact your administrator.