RIGOL DS6000 Series User Manual
Page 61

RIGOL
RP1003C/RP1004C/RP1005C User’s Guide
17
Rated Power
5.6W
Supply Voltage
+12V±0.5V
Maximum Rated Voltage
300V, CAT I (insulated conductor)
Gain Accuracy Period
1 year (opening/closing up to 10,000 times)
Effect of External
Magnetic Fields
≤20mA (DC and 60Hz, magnetic field of
400A/m)
RP1004C:
Bandwidth
DC to 100MHz (-3dB), refer to Appendix 1
Amplitude Characteristics (RP1004C)
Rise Time
≤3.5ns
Linear Response Range of
Input Current
30Arms, refer to Appendix 2 Relation
between Max Input Current and
Frequency (RP1004C)
Maximum Peak Current
50A peak, non-continuous
Gain
0.1V/A
Gain Accuracy
±1.0%rdg±1mV, ≤30A
±2.0%rdg, 30A to 50A peak (DC and 45Hz
to 66Hz, within the linear response range of
the input current)
Noise
≤2.5mArms (for 20MHz band measuring
instrument)
Input Impedance
Refer to Appendix 3 Input Impedance
(Typical) (RP1004C)
Gain Accuracy Drift
≤±2% (0℃ to 40℃ temperature, input of
50Hz, 30A)
Rated Power
5.3W
Supply Voltage
+12V±0.5V
Maximum Rated Voltage
300V, CATI (insulated conductor)
Gain Accuracy Period