Connections, Connectors labeling, Caution – Precision Digital PD6400 User Manual
Page 18: Warning
![background image](https://www.manualsdir.com/files/858256/content/doc018.png)
Model PD6400 High Voltage & Current Meter
Instruction Manual
18
Connections
All connections are made to removable screw terminal connectors
located at the rear of the meter.
Caution!
Use copper wire with 60°C or 60/75°C insulation for all line
voltage connections. Observe all safety regulations.
Electrical wiring should be performed in accordance with
all applicable national, state, and local codes to prevent
damage to the meter and ensure personnel safety.
Connectors Labeling
The connectors’ label, affixed to the meter, shows the location of all
connectors available with requested configuration.
Warning!
Do not connect any equipment other than Precision
Digital’s expansion modules, cables, or meters to the
RJ45 M-LINK connector. Otherwise damage will occur
to the equipment and the meter.
Figure 6. Connector Labeling for Fully Loaded PD6400
+
M-LINK
1
2
3
4
5
6
7
8
1
2
POWER
SIGNAL
V+
V-
F4
COM
2
1
4
3
2
1
I+
I-
AC
TYPE
DC
MA OUT
2
1
I-
I+
R
3
RELAY4
RELAY3
4
3
6
5
2
1
RELAY2
RELAY1
4
3
6
5
2
1
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO