beautypg.com

Problems/causes/solutions, Anomaly possible causes solutions – MCZ Tube 2013 User Manual

Page 51

background image

49

11-PROBLEMS/CAUSES/SOLUTIONS

Technical Dept. - All rights reserved - Reproduction is prohibited

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

The product always runs at maximum

power when in automatic mode.

The room thermostat is in the maximum

position.

Set the thermostat temperature again.

Faulty temperature probe.

Check the probe and replace it, if necessary.

Faulty or malfunctioning control panel.

Check the panel and replace it, if necessary.

Thermostat is set to minimum.

Set the thermostat temperature again.

The product does not go on.

No power supply.

Check that the plug is inserted and the

main switch is in the “I” position.

Faulty pellet probe.

Wait for the water or pellet tank to cool

down and restart the product.

Blown fuse.

Replace the fuse.

Clogged smoke exhaust or smoke duct.

Clean the smoke exhaust and/or the

smoke duct.

An alarm has been triggered.

Verify the type of alarm and proceed

accordingly.

Verify whether the brazier is clean.

Clean the brazier from any fouling or

residue of unburned pellets.

Check the position of the brazier.

Reposition the brazier on its seat.

Check that the spark plug gets hot.

Check the replace it, if necessary.