TEST

FEED SCREW LOADING

This function can only be activated when the stove is off and allows the pellets to be loaded into the feed screw (loading system). It can

be used each time the pellets finish in the feed screw and hopper (see alarm A02). It is useful to prevent failed start-ups (alarm A01) due

to the hopper being empty.

The LOAD FEED SCREW function is activated as follows (with the stove off): bring selector “D” on the emergency panel to OFF and press the

TEST on the same panel three consecutive times. Wait a few seconds and FEED SCREW will flash on the display.

Press the TEST key once again when the pellets begin to fall into the brazier to end the LOAD FEED SCREW function and proceed with the

stove start-up.