10-MAINTENANCE AND CLEANING

Technical Dept. - All rights reserved - Reproduction is prohibited

REMOVING THE AIR FILTER FOR CLEANING PURPOSES

CLEANING THE AIR FILTER

The metal mesh air filter is inserted in the rear part of the product, in line with the Ø 5 cm combustion air inlet pipe, and its aim is to

prevent dirt from entering the motor body and the internal sensor.

It is recommended to verify the filter is clean every 15/20 days. If necessary, remove the lint or material deposited on it. It must be cleaned

more often if there are pets inside the house. Simply remove the knob that blocks the filter on the air inlet pipe and extract the filter by

turning it in the direction indicated by the arrow. Use a brush, a damp cloth or compressed air to clean it.

The filter consists of metal mesh and is soft and can be deformed, therefore be careful when cleaning it so as to

prevent crushing or ruining it. It must be replaced if it tears.

ATTENTION!

The product must never be operated without the air filter. The manufacturer cannot be held liable for any damage

caused to the internal components if this requirement is not complied with.

PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN

CLEANING THE HEAT EXCHANGER

The compartment through which the exhaust smoke passes must be cleaned at the end of the winter season.

This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes very difficult to

remove it due to the humidity compacting it over time.

It is good practice to guarantee effective ventilation in the room while cleaning the product.