11-PROBLEMS/CAUSES/SOLUTIONS

Technical Dept. - All rights reserved - Reproduction is prohibited

ATTENTION!

All repairs must only be carried out by a specialised technician, with the product switched off and the plug

disconnected.

If the product is NOT used as described in this manual, the manufacturer declines all liability for any damage caused

to persons and property.

All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and

repairs.

• Do not tamper with the safety devices.

• Do not remove the safety devices.

• Connect the product to an efficient smoke expulsion system.

• Verify that the room in which the appliance will be installed is adequately ventilated.

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

Pellets not being fed into the

combustion chamber.

The pellet hopper is empty.

Fill the hopper with pellets.

Sawdust has blocked the feed screw.

Empty the hopper and remove the sawdust

from the feed screw by hand.

Faulty gear motor.

Replace the gear motor.

Faulty electronic board.

Replace the circuit board.

The fire goes out or the appliance

stops automatically.

The pellet hopper is empty.

Fill the hopper with pellets.

The pellets are not fed.

See the previous anomaly.

The pellet temperature safety probe has

been triggered.

Let the product cool down, restore the

thermostat until the problem is resolved

and switch the product back on. If the

problem persists contact Technical

Assistance.

The door is not closed properly or the

gaskets are worn.

Close the door and replace the gaskets with

original ones.

Unsuitable pellets.

Change the type of pellets with those

recommended by the manufacturer.

Low pellet supply.

Have the fuel flow rate checked by Technical

Assistance.

The combustion chamber is dirty.

Clean the combustion chamber in

accordance with the installation guide.

Clogged outlet.

Clean the smoke duct.

Faulty smoke extraction motor.

Check the motor and replace it, if necessary.

Triggered clogged flue alarm.

Verify whether the smoke duct is clogged.