Installation Instructions

The following sections explain the installation of the CVEQ 100

and SVEQ 100 series of line drivers.

Installing the CVEQ 100/SVEQ 100

Mounting the CVEQ 100 and SVEQ 100

The CVEQ 100 composite video line driver and the SVEQ 100

S-video line driver can be set on a table, mounted on a rack

shelf, mounted under a desk or table, mounted through

furniture (CVEQ 100 only), or mounted on the back of a rack

(SVEQ 100 only).

Tabletop use

Four self-adhesive rubber feet are included with the line driver.
For tabletop use, attach one foot at each corner of the bottom

side of the unit and place the unit in the desired location. See

chapter 3 for details on wiring and switch settings.

UL rack mounting guidelines

The following Underwriters Laboratories (UL) guidelines

pertain to the safe installation of the line drivers in a rack.
1

.

Elevated operating ambient temperature — If installed in a

closed or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater than

room ambient temperature. Therefore, install the line

driver in an environment compatible with the maximum

ambient temperature (Tma = +122 °F, +50 °C) specified by

Extron.

2

.

Reduced air flow — Install the equipment in a rack so that

the amount of air flow required for safe operation of the

equipment is not compromised.

3

.

Mechanical loading — Mount the equipment in the rack so

that a hazardous condition is not achieved due to uneven

mechanical loading.

4

.

Circuit overloading — Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing this

concern.

5

.

Reliable earthing (grounding) — Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (e.g. use of power strips).

Rack mounting

For rack mounting, do not install the rubber feet. Mount

the distribution amplifier on a 19" wide 1U VersaTools

®

rack

shelf (Extron RSF 123, part #60-190-20; Extron RSB 123, part

#60-604-21), a standard 1U Universal or Basic rack shelf (Extron

RSU 129, part #60-190-01; Extron RSB 129, part #60-604-02), or a

Universal or Basic 1U 6-inch deep rack shelf (Extron RSU 126,

part #60-190-10; Extron RSB 126, part #60-604-11).
1

.

If feet were previously installed on the bottom of the line

driver, remove them.

2

.

Mount the line driver on the rack shelf, using two

4-40 x 3/16" screws in opposite (diagonal) corners to

secure the unit to the shelf.

3

.

Install blank panel(s) or other unit(s) on the rack shelf.

QuarterRackVersaToolsShelf

(2) 4-40 x 3/16"
Screws

Use 2 mounting holes on
opposite corners.

VersaTools Rack Shelf

1/4 Rack Width Front
False Faceplate

Mounting the line driver on a VersaTools rack shelf