3-13

C

Power supply voltage polarity is critical. Incorrect

voltage polarity can damage the power supply and the

line driver. Identify the power cord negative lead by

the ridges on the side of the cord.

To verify the polarity before connection, plug in the power

supply with no load and check the output with a voltmeter.

W

The two power cord wires must be kept separate while

the power supply is plugged in. Remove power before

wiring.

N

Do not tin the power supply leads before installing in the

direct insertion connector. Tinned wires are not as secure
in the connectors and could be pulled out.

Gain adjustment control

The gain control adjusts picture brightness by compensating

for signal amplitude loss caused by cable resistance. To adjust

the output gain, view the display while using a small, flat-blade

screwdriver to rotate the potentiometer. This control produces a

gain adjustment ranging from -1 dB to + 3 dB (CVEQ and luma

of SVEQ) and from 0 dB to +10 dB (chroma of SVEQ). Select the

setting that gives the best picture brightness.

CVEQ 100 Series

SVEQ 100 Series

N

The gain control is a potentiometer with a mechanical stop

at the high and the low end. After you have reached the

high or low end of the adjustment, no change is apparent
on the display. The default is unity (the dot position)

You can judge the adjustment visually by viewing the display.

For a more precise setting use an oscilloscope or a waveform

monitor connected to the far end of the output cable, and adjust

the gain so that the level at the waveform monitor is 100 IRE.

Equalization (EQ) adjustment control

The equalization control adjusts the output level and peaking

to get a sharp picture. This adjustment changes the level and

peaking of the output signal to compensate for capacitance

caused by up to 1000 feet (300 meters) of Extron MHR cable.
This control produces an equalization adjustment ranging from

0 dB to + 7 dB (CVEQ and luma of SVEQ).

CVEQ 100 Series

SVEQ 100 Series

Use a small, flat-blade screwdriver to rotate this control. View

the display and select the setting that gives the sharpest picture.

For a more precise setting, you can use an oscilloscope or a

waveform monitor connected to the far end of the output

cable, and adjust the equalization so that the color burst ranges

between -20 IRE and +20 IRE.

N

The EQ control is a potentiometer with a mechanical stop

at the high and the low end. After you have reached the

high or low end of the adjustment, no change is apparent
on the display. The default is set to 0 dB (the dot position)

.

Replacing the Decora Faceplate (CVEQ 100 D

and SVEQ 100 D)

The front faceplate is replaced by removing the two rear panel

mounting screws, replacing the faceplate, then reattaching the

two screws, as shown in the CVEQ 100 D example below.

N

The faceplate for the SVEQ 100 D is replaced in similar

fashion.

Faceplate (rear)

Rear Panel

Mounting
Screws

Removing the CVEQ 100 D faceplate

This manual is related to the following products: