Condition possible cause corrective action, Fig 4 – Sealey CPG12V User Manual
Page 3

4. TROUbLESHOOTING
3.5 bULk FILLING
3.5.1 Press the catch plate to release the plunger handle.
3.5.2 Connect a low pressure bulk greasing unit to the bulk filler nipple at the top of
the gun and fill until plunger is fully extended.
3.5.3 Press and hold the catch plate and push the plunger handle down until some
resistance is felt.
3.5.4 Open the pressure release valve until grease appears.
3.6 PRIMING THE GUN
3.6.1 Before loading the gun with a cartridge or filling via a grease bucket, it is ideal
to prime the gun.
3.6.2 To prime the gun simply pack grease into the cavity located at the entrance of
the gun assembly (where the grease tube screws into the gun) and operate the
trigger, this will induce the intake of grease into the gun assembly.
3.7 OPERATION
3.7.1 To operate the gun simply push the grease outlet onto the the grease nipple
and operate the trigger until the desired amount of grease has been
dispersed.
3.7.2 If you encounter air pockets during operation simply exert force on the
plunger (Fig 4.1), press the pressure release valve (Fig 4.2) and operate
trigger (Fig 4.3) in short, sharp bursts until grease begins to flow from the nozzle.
3.7.3 When the grease gun is not in use turn the locking button (Fig 4.4) to the “lock” position
3.7.4 To check the remaining battery power, press and hold down the lED display button on the top of the grease gun.
A gauge will appear on the display, showing the percentage of battery charge left.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole Uk distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
CPG12V.V2 Issue: 3 - 19/12/11
Condition
Possible Cause
Corrective Action
Motor fails to run.
- Battery needs recharging.
- Faulty wiring to motor.
- Recharge battery.
- Remove battery, disassemble
handle and check wiring for loose
connections.
Pressure release valve opens to
discharge grease.
- Blocked line.
- Blocked bearing.
- Blocked grease fitting.
- Check lines, pipe joints and
grease fittings and remove any
obstructions.
Grease gun fails to dispense
grease.
- Grease tube is out of grease.
- loss of prime.
- Check valve is not functioning.
- Check that the tube contains
grease.
- Repeat priming operation.
- Remove check valve, clean and
inspect the valve seat.
Grease gun continues to lose
prime.
- Air may be trapped in locations
throughout the grease tube ass’y
after bulk filling.
- Grease tube follower may be
binding.
- Empty grease tube ass’y, refill and
repeat priming operation.
- Replace grease tube ass’y.
Battery fails to charge.
- Charger may not have power.
- Battery may be dead.
- Check the mains charger is
providing power.
Fig 4