beautypg.com

Fig.4 fig.5, Yk759fah, Declaration of conformity 5. maintenance – Sealey YK509FAH User Manual

Page 4

background image

Declaration of Conformity We, the sole importer into the uK, declare that the products listed below are in conformity with the following

EEc standards and directives.

The construction files for these products are held by the Manufacturer

and may be inspected on request by contacting Jack Sealey Ltd

For Jack Sealey Ltd. Sole importer into the UK of Sealey Quality Machinery

Air Hydraulic Floor Press Models

YK509FAH

YK759FAH

2006/42/Ec Machinery Directive

93/68/EEc cE Marking Directive

Signed by Mark Sweetman

2nd September 2008

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole uK Distributor,

Sealey Group,

Bury St. Edmunds,

Suffolk.

01284 757500

[email protected]

01284 703534

e-mail

Web

www.sealey.co.uk

6. DECLARATION OF CONFORMITY

5. MAINTENANCE

IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE PRESS.

Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.

DO NOT RETURN PRODUCT TO US. Please telephone us on 01284 757500 to obtain the address and phone number of your local agent.

If product is under guarantee please contact your dealer.

De-commissioning Product

Should the product become completely unserviceable and require disposal, draw off the oil into an approved container and dispose

of the product and the oil according to local regulations.

YK509FAH & YK759FAH

Issue no: 1 - 02/09/08

Note: Maintenance and repair must only be carried out by qualified person. contact your Sealey dealer for details.

5.1

Always keep the press clean, dry and lubricate all moving parts at regular intervals.

5.2

When not in use always store in a dry location with the piston retracted.

5.3

Should you need to check or replace oil ensure piston is fully retracted. Remove the oil reservoir filler plug and top up using Sealey

hydraulic jack oil.

DO NOT use brake fluid. contact your local Sealey dealer for details. After filling purge the system to remove any air.

Fig.4

Fig.5

DANGER! Press's are purpose designed to withstand greater loads than

the hydraulic units can develop. For safety reasons, always ensure the

workpiece is secured on the table to ensure loads that flex will not

suddenly “give” causing danger to operator or damage to component.

Ensure you have read and understood chapter 1 safety instructions.

4.2

OPERATING INSTRUCTIONS.

4.2.1 connect the air valve to the air supply.

4.2.2 Set the bed frame at the desired height, if adjustment is required, turn

the hand winch until the cable just takes the weight of the bed frame,

remove the safety clips (13) from the back of the pins (12), see Fig.4 and

withdraw the pins. use the hand winch to raise or lower the bed frame to

the height required, insert pins and safety clips (Fig.5). Slacken off the

hand winch so that the pins are taking the full weight of the bed frame.

4.2.3 check that the release valve on the hydraulic unit is fully closed, ready

for operation.

4.2.4 Locate the flat pressing plates or the v-blocks on to the bed frame, push

down the locating pins to ensure the plates do not slip. Place workpiece

onto the plates and position the head of the hydraulic unit on the centre

of the workpiece using an appropriate extension.

Note: care must be

taken to ensure the plates do not fall from the bed frame.

WARNING! DO NOT apply off centre loads.

4.2.5 When work is complete turn the release valve anti-clockwise to release

the pressure and the piston and the ram head will retract automatically.

Note: Always keep the piston retracted after use.

4.2.6 Disconnect the air valve from the air supply.

YK759FAH