4.1

INSTALLATION.

4.1.1 Securely attach the press to a flat, firm, level surface taking

into account clearance for working pieces.

DANGER! The press is top heavy. If it requires moving after

assembly or for relocation, use suitable slings around the top

crossbeam, or lift direct with a forklift with the forks located

under the top crossbeam.

DO NOT use a pallet truck.

4.1.2 connect to an air supply as recommended in Fig.3. The air

supply must be capable of 108 to 123psi and 9cfm.

4.1.3

Purge hydraulic system. Before operating the press, the

hydraulic system may require purging in order to eliminate

any air that may have built up during transit.

Manual Operating System: open the release valve by turning anti-clockwise and pump the handle several times.

Air Operating System: open the release valve by turning anti-clockwise and connect the air valve to the air line system, operate the

air valve, allowing the pump to operate until the air has been purged. Should the system malfunction at any time, repeating either of

these procedures may resolve the problem.